Specifications
Product Type | PDU |
---|
Product Series | Switched |
---|
Brand Name | Server Technology |
---|
Manufacturer | Server Technology, Inc |
---|
Product Model | CX-16HF2A452 |
---|
Product Name | Sentry Switched CX-16HF2A452 16-Outlet PDU |
---|
Product Line | Sentry |
---|
Manufacturer Part Number | CX-16HF2A452 |
---|
Manufacturer Website Address | http://www.servertech.com |
---|
Environmentally Friendly | Yes |
---|
Environmental Certification | cTUVusRoHSWEEET�V |
---|
Package Contents | - Sentry Switched CX-16HF2A452 16-Outlet PDU
- 1 x Probe
|
---|
Network (RJ-45) | Yes |
---|
Height | 17.2" |
---|
Width | 3.5" |
---|
Depth | 10" |
---|
Rack Height | 2U |
---|
Form Factor | Rack-mountable |
---|
Input Receptacles | 2 x IEC 60320 C20 |
---|
Output Receptacles | 16 x IEC 60320 C13 |
---|
Protection Type | Overload ProtectionCircuit Protection |
---|
Input Current | 20 A |
---|
Input Voltage | 230 V AC |
---|
Management | Communications and Security: - 10/100 Mbps Ethernet (RJ-45 connector)
- RS-232 serial (RJ-45 connector)
- Two (2) temperature/humidity sensor inputs (4P4C)
- Link port (RJ-12)
- Web-browser GUI and command-line-interface (CLI)
- HTTP/HTTPS
- TLSv1
- SSHv2
- Telnet
- SNMPv3 and v3 (GET,SET, Traps)
- IPv4 and IPv6
- LDAPv3/LDAPS
- TACACS+
- RADIUS
|
---|
Limited Warranty | 2 Year |
Description
Switched Fail-Safe Transfer SwitchThe Sentry CW-16HF2 provides fail-over redundancy to single or dual-power supply servers and network devices. Exclusive to the Sentry Switched Fail-Safe family is its ability to carry loads on the A circuit, B circuit or both and to remotely manage the outlets.Similar, but unlike a common automatic transfer switch, the Sentry Switched Fail-Safe unit is unique in that it contains two (2) in-feeds with two (2) banks of eight (8) outlets each, for a total of 16 outlets across the two circuits.The "A" infeed routinely powers just the A1-8 outlets, and the "B" in-feed routinely powers just the B1-8 outlets. However, if the "A" infeed goes down, the "B" infeed powers all 16 outlets and if the "B" infeed goes down , the "A" infeed powers all the outlets. This "Fail-Safe" method has several advantages compared to a standard ATS because it does not prohibit load balancing between the two supplied circuits. A standard ATS contains two in-feeds, but runs all outlets from just one source, with the secondary source only being used once an outage occurs on the primary infeed. The "Fail-Safe" method diers in that both circuits are routinely loaded, but only to half capacity. This results in less heat and consequently less of a voltage drop compared to the same load existing on just one source. Only when an outage occurs on one of the two sources will the entire load be applied to a single source